Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transplantation ; 108(2): 464-472, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38259179

RESUMO

BACKGROUND: Children are removed from the liver transplant waitlist because of death or progressive illness. Size mismatch accounts for 30% of organ refusal. This study aimed to demonstrate that 3-dimensional (3D) technology is a feasible and accurate adjunct to organ allocation and living donor selection process. METHODS: This prospective multicenter study included pediatric liver transplant candidates and living donors from January 2020 to February 2023. Patient-specific, 3D-printed liver models were used for anatomic planning, real-time evaluation during organ procurement, and surgical navigation. The primary outcome was to determine model accuracy. The secondary outcome was to determine the impact of outcomes in living donor hepatectomy. Study groups were analyzed using propensity score matching with a retrospective cohort. RESULTS: Twenty-eight recipients were included. The median percentage error was -0.6% for 3D models and had the highest correlation to the actual liver explant (Pearson's R = 0.96, P < 0.001) compared with other volume calculation methods. Patient and graft survival were comparable. From 41 living donors, the median percentage error of the allograft was 12.4%. The donor-matched study group had lower central line utilization (21.4% versus 75%, P = 0.045), shorter length of stay (4 versus 7 d, P = 0.003), and lower mean comprehensive complication index (3 versus 21, P = 0.014). CONCLUSIONS: Three-dimensional volume is highly correlated with actual liver explant volume and may vary across different allografts for living donation. The addition of 3D-printed liver models during the transplant evaluation and organ procurement process is a feasible and safe adjunct to the perioperative decision-making process.


Assuntos
Transplante de Fígado , Modelos Anatômicos , Criança , Humanos , Fígado , Doadores Vivos , Estudos Prospectivos , Estudos Retrospectivos , Impressão Tridimensional
2.
J Surg Case Rep ; 2020(9): rjaa370, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33005326

RESUMO

Liver resection for metastatic cancer has become the standard of care for specific groups of patients, including noncolorectal non-neuroendocrine liver metastases (NCNNELM). Liver metastasis from differentiated thyroid carcinoma is considered rare, with an approximated frequency of 0.5%. We present a case of metastatic papillary thyroid carcinoma (PTC) to the liver and literature review. Herein, we report a 72-year-old male that underwent formal left hepatectomy for 4.4 cm metastatic PTC generating left bile duct obstruction. Two months after, presented with multiple small lesions within the hepatic parenchyma and diffuse ductal dilatation of the right biliary system. Therefore, treated with a percutaneous biliary drain placement without complications. In a patient diagnosed with initial Stage II PTC, undergoing total thyroidectomy 10 years before presenting to the clinic. Bearing over a decade of treatments for local and distal recurrences. We believe approaching strategies for this specific disease should be developed to establish standard management.

3.
3D Print Med ; 6(1): 24, 2020 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-32965536

RESUMO

BACKGROUND: Medical 3D printing as a component of care for adults with cardiovascular diseases has expanded dramatically. A writing group composed of the Radiological Society of North America (RSNA) Special Interest Group on 3D Printing (SIG) provides appropriateness criteria for adult cardiac 3D printing indications. METHODS: A structured literature search was conducted to identify all relevant articles using 3D printing technology associated with a number of adult cardiac indications, physiologic, and pathologic processes. Each study was vetted by the authors and graded according to published guidelines. RESULTS: Evidence-based appropriateness guidelines are provided for the following areas in adult cardiac care; cardiac fundamentals, perioperative and intraoperative care, coronary disease and ischemic heart disease, complications of myocardial infarction, valve disease, cardiac arrhythmias, cardiac neoplasm, cardiac transplant and mechanical circulatory support, heart failure, preventative cardiology, cardiac and pericardial disease and cardiac trauma. CONCLUSIONS: Adoption of common clinical standards regarding appropriate use, information and material management, and quality control are needed to ensure the greatest possible clinical benefit from 3D printing. This consensus guideline document, created by the members of the RSNA 3D printing Special Interest Group, will provide a reference for clinical standards of 3D printing for adult cardiac indications.

4.
World J Urol ; 36(5): 733-743, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29546508

RESUMO

PURPOSE: Despite the increasing use of advanced 3D imaging techniques and 3D printing, these techniques have not yet been comprehensively compared in a surgical setting. The purpose of this study is to explore the effectiveness of five different advanced imaging modalities during a complex renal surgical procedure. METHODS: A patient with a horseshoe kidney and multiple large, symptomatic stones that had failed Extracorporeal Shock Wave Lithotripsy (ESWL) and ureteroscopy treatment was used for this evaluation. CT data were used to generate five different imaging modalities, including a 3D printed model, three different volume rendered models, and a geometric CAD model. A survey was used to evaluate the quality and breadth of the imaging modalities during four different phases of the laparoscopic procedure. RESULTS: In the case of a complex kidney procedure, the CAD model, 3D print, volume render on an autostereoscopic 3D display, interactive and basic volume render models demonstrated added insight and complemented the surgical procedure. CAD manual segmentation allowed tissue layers and/or kidney stones to be made colorful and semi-transparent, allowing easier navigation through abnormal vasculature. The 3D print allowed for simultaneous visualization of renal pelvis and surrounding vasculature. CONCLUSIONS: Our preliminary exploration indicates that various advanced imaging modalities, when properly utilized and supported during surgery, can be useful in complementing the CT data and laparoscopic display. This study suggests that various imaging modalities, such as ones utilized in this case, can be beneficial intraoperatively depending on the surgical step involved and may be more helpful than 3D printed models. We also present factors to consider when evaluating advanced imaging modalities during complex surgery.


Assuntos
Rim Fundido , Processamento de Imagem Assistida por Computador , Cuidados Intraoperatórios/métodos , Cálculos Renais , Rim , Procedimentos Cirúrgicos Urológicos , Rim Fundido/diagnóstico , Rim Fundido/cirurgia , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Cálculos Renais/diagnóstico , Cálculos Renais/cirurgia , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Impressão Tridimensional , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Procedimentos Cirúrgicos Urológicos/instrumentação , Procedimentos Cirúrgicos Urológicos/métodos
5.
Surg Endosc ; 29(9): 2500-5, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25537377

RESUMO

BACKGROUND: Many factors can affect a surgeon's performance in the operating room; these may include surgeon comfort, ergonomics of tool handle design, and fatigue. A laparoscopic tool handle designed with ergonomic considerations (pistol grip) was tested against a current market tool with a traditional pinch grip handle. The goal of this study is to quantify the impact ergonomic design considerations which have on surgeon performance. We hypothesized that there will be measurable differences between the efficiency while performing FLS surgical trainer tasks when using both tool handle designs in three categories: time to completion, technical skill, and subjective user ratings. METHODS: The pistol grip incorporates an ergonomic interface intended to reduce contact stress points on the hand and fingers, promote a more neutral operating wrist posture, and reduce hand tremor and fatigue. The traditional pinch grip is a laparoscopic tool developed by Stryker Inc. widely used during minimal invasive surgery. Twenty-three (13 M, 10 F) participants with no existing upper extremity musculoskeletal disorders or experience performing laparoscopic procedures were selected to perform in this study. During a training session prior to testing, participants performed practice trials in a SAGES FLS trainer with both tools. During data collection, participants performed three evaluation tasks using both handle designs (order was randomized, and each trial completed three times). The tasks consisted of FLS peg transfer, cutting, and suturing tasks. RESULTS: Feedback from test participants indicated that they significantly preferred the ergonomic pistol grip in every category (p < 0.05); most notably, participants experienced greater degrees of discomfort in their hands after using the pinch grip tool. Furthermore, participants completed cutting and peg transfer tasks in a shorter time duration (p < 0.05) with the pistol grip than with the pinch grip design; there was no significant difference between completion times for the suturing task. Finally, there was no significant interaction between tool type and errors made during trials. CONCLUSIONS: There was a significant preference for as well as lower pain experienced during use of the pistol grip tool as seen from the survey feedback. Both evaluation tasks (cutting and peg transfer) were also completed significantly faster with the pistol grip tool. Finally, due to the high degree of variability in the error data, it was not possible to draw any meaningful conclusions about the effect of tool design on the number or degree of errors made.


Assuntos
Ergonomia , Mãos/fisiologia , Laparoscópios/normas , Laparoscopia/instrumentação , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...